Résumé

This article delineates the development of an advanced ratiometric pH optode designed for protracted monitoring of pH dynamics in cementitious materials—a crucial aspect of structural management. The optode features a dual-layer Hydromed™ D4 polymer pellet incorporating a pH-sensitive Naphth-AlkyneOMe fluorescent probe (pKa ≈ 12) and CdSe quantum dots as an internal reference. The polymer matrix, optimized with diamond powder and carbon black, enhances the signal while minimizing light artifacts. Demonstrating a robust response to pH fluctuations, the optode, utilizing ratiometric measurements, enables steadfast monitoring for up to 75 days. The experimental setup includes a Delrin® sample compartment housing a glass slide with the optode connected to an optical fiber via an SMA connector. HydroMed™ D4 films, forming the pH-sensitive layer, are deposited on the glass slide and secured. The optode configuration is fine-tuned to optimize signal intensity by reducing its length. For optode-detector coupling, a 1000 µm core diameter optical fiber links the optode, and a 405 nm LED illuminates the sensing film. The emission signal is collected through the optical fiber, and signals are processed using computer-controlled lock-in amplifiers. In the investigation of hydroxide ion diffusion through a concrete sample, the optode's efficacy was validated, aligning with pH electrode measurements. Addressing long-term stability, a degradation model uncovered leisurely kinetics with commendable stability. Slow degradation kinetics, with a reaction rate coefficient of 1.6 × 10⁻⁷ s⁻¹ and a half-life of 1180 h, exceeded expectations. This pH optode, showcasing an accurate and resilient response to pH variations within the 10 to 12.5 range, stands as a promising tool for monitoring pH dynamics in low-pH cementitious materials. The incorporation of a degradation model underscores fidelity over prolonged durations and offers a blueprint for enduring surveillance of concrete structures.
Fichier principal
Vignette du fichier
Sensoractdef2_HAL.pdf (1.46 Mo) Télécharger le fichier
Origine Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-04573549 , version 1 (13-05-2024)

Identifiants

Citer

Ayedah Tariq, Rasta Ghasemi, Jean Pierre Lefevre, Cédric Mongin, Alexandre Dauzères, et al.. Ratiometric fiber optic fluorescent pH sensor for hydroxide diffusion measurements in concrete. Sensors and Actuators B: Chemical, 2024, 405, pp.135297. ⟨10.1016/j.snb.2024.135297⟩. ⟨hal-04573549⟩
15 Consultations
19 Téléchargements

Altmetric

Partager

Gmail Mastodon Facebook X LinkedIn More