Quantification of curium isotopes in environmental samples: drawbacks, speciation and specific tracer - IRSN - Institut de radioprotection et de sûreté nucléaire
Article Dans Une Revue Journal of Radioanalytical and Nuclear Chemistry Année : 2021

Quantification of curium isotopes in environmental samples: drawbacks, speciation and specific tracer

Résumé

In this study, drawbacks of the use of 243Am as a tracer in order to quantify curium isotopes during a complex chemical procedure were highlighted. Origins of these drawbacks were investigated through a speciation computation simulation. This simulation was based on the compilation of over 50 constants and allowed to confirm that in order to quantify curium isotopes, more reliable results are obtained using a specific curium isotope as a tracer. A new curium standard was then characterized and used to quantify a wide 244Cm activity range in environmental samples. Obtained results were in excellent agreement with spiked activities and more consistent than those obtained when using a 243Am tracer.

Domaines

Chimie
Fichier principal
Vignette du fichier
0000169552_001.PDF (3.86 Mo) Télécharger le fichier
Origine Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-03368652 , version 1 (06-10-2021)

Identifiants

Citer

Azza Habibi, Roselyne Le Corre, Christele Wampach Aubert, Sandrine Fleury, Patricia Hennequet, et al.. Quantification of curium isotopes in environmental samples: drawbacks, speciation and specific tracer. Journal of Radioanalytical and Nuclear Chemistry, 2021, 329 (2), pp.545-554. ⟨10.1007/s10967-021-07751-7⟩. ⟨hal-03368652⟩